< Home

Configuring MEth Management Interface Attributes

Context

The MEth0/0/1 management interface is a special Ethernet interface that allows users to log in to the device to perform configuration and management operations. It can be assigned an IP address. The MEth management interface does not transmit services.

For details on how to log in to the device through the management interface, see S2720, S5700, and S6700 V200R019C10 Configuration Guide - Basic Configuration.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run interface meth 0/0/1

    The MEth management interface view is displayed.

  3. Run undo negotiation auto

    The MEth management interface is configured to work in non-auto-negotiation mode.

    By default, the MEth management interface works in auto-negotiation mode.

    When the management interface works in auto-negotiation mode, the rate and duplex mode cannot be configured on the interface.

    Interfaces at both ends of a link must use the same auto-negotiation mode. The interfaces cannot communicate with each other if they use different auto-negotiation modes.

  4. Run speed { 10 | 100 }

    The rate is configured for the MEth management interface.

    By default, the MEth management interface works at the maximum rate of 100 Mbit/s.

  5. Run duplex { full | half }

    The duplex mode is configured for the MEth management interface.

    By default, the MEth management interface works in full-duplex mode.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >