BFD parameters on the egress node include the local and remote discriminators, intervals for sending and receiving BFD packets, and local BFD detection multiplier. The BFD parameters affect BFD session setup.
You can adjust the local detection time according to the network situation. On an unstable link, if a small detection time is used, a BFD session may flap. You can increase the detection time of the BFD session.
Actual interval for the local device to send BFD packets = MAX {locally configured interval for sending BFD packets, remotely configured interval for receiving BFD packets}
Actual interval for the local device to receive BFD packets = MAX {remotely configured interval for sending BFD packets, locally configured interval for receiving BFD packets}
Local detection time = Actual interval for receiving BFD packets x Remotely configured BFD detection multiplier
Perform the following steps on the egress node of the LSP.
The system view is displayed.
This node is enabled with global BFD. The global BFD view is displayed.
By default, global BFD is disabled.
Return to the system view.
For the IP link, run bfd cfg-name bind peer-ip peer-ip [ vpn-instance vpn-instance-name ] [ interface interface-type interface-number ] [ source-ip source-ip ]
For the dynamic LSP, run bfd cfg-name bind ldp-lsp peer-ip ip-address nexthop ip-address [ interface interface-type interface-number ]
For the static LSP, run bfd cfg-name bind static-lsp lsp-name
For MPLS TE, run bfd cfg-name bind mpls-te interface tunnel interface-number [ te-lsp [ backup ] ]
Run discriminator local discr-value
The local discriminator is configured.
Run discriminator remote discr-value
The remote discriminator is configured.
The local identifier and remote identifier on both ends of a BFD session must accord with each other. The session cannot be established correctly otherwise. In addition, the local identifier and remote identifier cannot be modified after configuration.
The interval for sending BFD packets is set on the local device.
The interval for receiving BFD packets is set on the local device.
The local BFD detection multiplier is set.
The default value is 3.
The changes of the BFD session status can be advertised to the upper-layer application.
By default, a static BFD session cannot report faults of the monitored service module to the system.
If an LSP is used as a reverse tunnel to notify the ingress of a fault, you can run this command to allow the reverse tunnel to switch traffic if the BFD session goes Down. If a single-hop IP link is used as a reverse tunnel, this command can be configured. Because the process-pst command can be only configured for BFD single-link detection.
The configuration is committed.