< Home

Adjusting Time Parameters for Join/Prune Messages

Context

Prune information encapsulated in a Join/Prune message, which is defined by the IPv6 PIM protocol to control multicast forwarding. When the upstream neighbor receives a Join/Prune message, it starts a timer and sets the timer value to the holdtime of the Join/Prune message. If the upstream neighbor does not receive any Join/Prune message before the timer expires, the upstream neighbor starts to forward multicast data to the downstream interface again.

The holdtime of Join/Prune messages is configured in the PIM-IPv6 view or interface view. If the holdtime is configured both in the PIM-IPv6 view and interface view, the configuration in the interface view takes effect.

Default Settings

Table 1 lists the default settings of time parameters for Join/Prune messages.

Table 1 Default settings of time parameters for Join/Prune messages
Parameter Default Setting

Holdtime of Join/Prune messages

210s

Procedure

  • Global configuration
    1. Run system-view

      The system view is displayed.

    2. Run pim-ipv6

      The PIM-IPv6 view is displayed.

    3. Run holdtime join-prune interval

      The holdtime of Join/Prune messages is configured.

  • Configuration on an interface
    1. Run system-view

      The system view is displayed.

    2. Run interface interface-type interface-number

      The interface view is displayed.

    3. (Optional) On an Ethernet interface, run undo portswitch

      The interface is switched to Layer 3 mode.

      By default, an Ethernet interface works in Layer 2 mode.

      Only the S5720-EI, S5720-HI, S5730-HI, S5731-H, S5731-S, S5731S-H, S5731S-S, S5732-H, S6720-EI, S6720-HI, S6720S-EI, S6730-H, S6730S-H, S6730-S, and S6730S-S support switching between Layer 2 and Layer 3 modes.

    4. Run pim ipv6 holdtime join-prune interval

      The holdtime of Join/Prune messages is configured.