(Optional) Configuring the Device to Allow High Inrush Current During Power-On

Context

High inrush current may be generated when a non-standard PD is powered on. In this case, the device cuts off the power of the PD to protect itself. If the device is required to provide power for the non-standard PD, it must allow high inrush current.
Allowing high inrush current may disable self-protection of the device and damage components of the device.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run poe high-inrush enable [ slot slot-id ]

    The device is configured to allow high inrush current during power-on.

    By default, the device does not allow high inrush power during power-on.