To create a dynamic PW, VCs using the same encapsulation type must have different IDs.
Perform the following operations on the PEs.
The system view is displayed.
The AC interface view is displayed.
The interface is switched to Layer 3 mode.
By default, an Ethernet interface works in Layer 2 mode.
Only the S5720-EI, S5720-HI, S5730-HI, S5731-H, S5731-S, S5731S-H, S5731S-S, S5732-H, S6720-EI, S6720-HI, S6720S-EI, S6730-H, S6730S-H, S6730-S, and S6730S-S support switching between Layer 2 and Layer 3 modes.
The combination of the VC ID and VC type must be unique on each node. The VC IDs at both ends of a switching PW can be the same.
Primary and secondary PWs must use the same control word; otherwise, many packets may be lost during service switching.
A dynamic PW requires that the IDs of VCs using the same encapsulation type are different. Changing the encapsulation type may cause a VC ID collision.
To enable label-based load balancing, specify a PW template before creating a dynamic PW.
A name is configured for the L2VPN service.
After a name is configured for the L2VPN service, you can maintain the L2VPN service by clicking the name directly on the NMS GUI.