When a host is connected to a SEP network using a SmartLink group, the host sends SmartLink Flush packets to inform the remote device in the SEP segment if devices in the SmartLink group experience an active/standby switchover. Therefore, devices in a SEP segment must be able to process SmartLink Flush packets.
The system view is displayed.
A SEP segment is created and the view of the SEP segment is displayed.
The device in a SEP segment is configured to process SmartLink Flush packets.
By default, no device in a SEP segment is configured to process SmartLink Flush packets.
Return to the system view.
The interface view is displayed.
The interface is configured to receive Flush packets.
By default, an interface is prohibited from receiving Flush packets.
The password parameter is optional. If no password is specified, no password is used for authentication.
The control VLAN ID and password contained in Flush packets on both devices must be the same.