< Home

Data Plan

The data provided in this section is used as an example, which may vary depending on the network scale and topology.

Table 1 MPLS parameters

Parameter

Value

Remarks

mpls te

-

Enable MPLS TE.

mpls rsvp-te

-

Enable MPLS RSVP-TE.

mpls rsvp-te hello

-

Enable the RSVP Hello extension mechanism.

mpls rsvp-te hello full-gr

-

Enable the RSVP GR and RSVP GR Helper capabilities of the GR node.

mpls te cspf

-

Enable the MPLS TE CSPF algorithm.

Table 2 MPLS TE tunnel parameters

Parameter

Value

Remarks

interface Tunnel

Number of a tunnel interface

It is recommended that tunnel IDs be associated with device names and descriptions be added for tunnel interfaces.

ip address unnumbered

interface LoopBack1

Configure a tunnel interface to borrow an IP address from loopback interface 1.

tunnel-protocol

mpls te

Enable the TE tunnel function.

destination

IP address of remote loopback interface 1

Specify the destination IP address.

mpls te tunnel-id

Tunnel ID

Set a tunnel ID.

mpls te affinity property

Configure the affinity attribute for the primary and backup CR-LSPs based on link management group attributes.

-

mpls te backup

hot-standby

Configure the hot standby mode of the tunnel.

bfd bind mpls-te interface Tunnel te-lsp

discriminator local

discriminator remote

detect-multiplier

min-tx-interval

min-rx-interval

process-pst

Configure static BFD to detect the backup CR-LSP of a TE tunnel.

Set the local discriminator of the local system to be the same as the remote discriminator of the remote system, and adjust the local detection multiplier of BFD.

Set the minimum interval at which BFD packets are sent and received to 3.3 ms.

Allow BFD sessions to change the PST to speed up switchovers.

bfd bind mpls-te interface Tunnel

discriminator local

discriminator remote

detect-multiplier

min-tx-interval

min-rx-interval

process-pst

Configure static BFD to detect the primary CR-LSP of a TE tunnel.

Set the local discriminator of the local system to be the same as the remote discriminator of the remote system, and adjust the local detection multiplier of BFD.

Set the minimum interval at which BFD packets are sent and received to 3.3 ms.

Allow BFD sessions to change the PST to speed up switchovers.

tunnel-policy

Tunnel policy name: TSel

tunnel select-seq cr-lsp lsp load-balance-number 1

Tunnel policy on the core device: TE

tunnel select-seq cr-lsp load-balance-number 1

Configure tunnel policies for preferentially selecting CR-LSPs.

Table 3 MPLS TE tunnel list

Tunnel

Tunnel Interface

Tunnel ID

Core_SPE1 to Site1_UPE1

Site1_UPE1 to Core_SPE1

Tunnel611

71

Core_SPE1 to Site1_UPE2

Site1_UPE2 to Core_SPE1

Tunnel622

82

Core_SPE1 to Site3_UPE5

Site3_UPE5 to Core_SPE1

Tunnel721

312

Core_SPE1 to Site3_UPE6

Site3_UPE6 to Core_SPE1

Tunnel711

311

Core_SPE2 to Site2_UPE3

Site2_UPE3 to Core_SPE2

Tunnel111

111

Core_SPE2 to Site2_UPE4

Site2_UPE4 to Core_SPE2

Tunnel121

121

Core_SPE2 to Site1_UPE1

Site1_UPE1 to Core_SPE2

Tunnel612

72

Core_SPE2 to Site1_UPE2

Site1_UPE2 to Core_SPE2

Tunnel621

81

Core_SPE3 to Site2_UPE3

Site2_UPE3 to Core_SPE3

Tunnel112

112

Core_SPE3 to Site2_UPE4

Site2_UPE4 to Core_SPE3

Tunnel122

122

Core_SPE3 to Site3_UPE5

Site3_UPE5 to Core_SPE3

Tunnel722

322

Core_SPE3 to Site3_UPE6

Site3_UPE6 to Core_SPE3

Tunnel712

321

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >