S5700-P-LI |
- V200R010 and earlier versions: last two SFP optical ports
- V200R011 and later versions: last four SFP optical ports
|
- 1 m passive SFP+ copper cable
- 10 m active SFP+ copper cable
- 3 m and 10 m AOC cables (supported in V200R003 and later versions)
- 6GE stack optical module (SFP-6GE-LR) and optical fiber (supported
in V200R007 and later versions)
- 0.5 m and 1.5 m SFP+ dedicated stack cable (supported in V200R011C10
and later versions)
|
- Using a 10 m SFP+ active high-speed copper: 5 Gbit/s
- Using other stack cable: 2.5 Gbit/s
|
- Any models of the S5700-P-LI series can set up a stack.
- V200R010 and earlier versions: A switch supports a maximum of
two logical stack ports, and each logical stack port contains one
stack member port. A switch supports a maximum of two stack member
ports.
- V200R011 and later versions: A switch supports a maximum of two
logical stack ports, and each logical stack port contains one or two
stack member ports. A switch supports a maximum of four stack member
ports. When one logical stack port contains two stack member ports,
the logical stack port can contain only stack member ports 1 and 2,
or 3 and 4.
|
S5700-TP-LI |
Two SFP optical ports |
- 1 m passive SFP+ copper cable
- 10 m active SFP+ copper cable
- 3 m and 10 m AOC cables
- 6GE stack optical module (SFP-6GE-LR) and optical fiber (supported
in V200R007 and later versions)
- 0.5 m and 1.5 m SFP+ dedicated stack cable (supported in V200R011C10
and later versions)
|
- Using a 10 m SFP+ active high-speed copper: 5 Gbit/s
- Using other stack cable: 2.5 Gbit/s
|
- Any models of the S5700-TP-LI series can set up a stack.
- A switch supports a maximum of two logical stack ports, and each logical stack port contains one or two stack member ports. Each switch can use a maximum of two service ports as stack member ports.
|
S5700-X-LI |
Four SFP+ optical ports |
- 1 m passive SFP+ copper cable
- 3 m passive SFP+ copper cable
- 5 m passive SFP+ copper cable (supported in V200R009 and later
versions)
- 10 m active SFP+ copper cable
- 3 m and 10 m AOC cables (supported in V200R003 and later versions)
- 10GE SFP+ optical module and optical fiber
- 0.5 m and 1.5 m SFP+ dedicated stack cable (supported in V200R011C10
and later versions)
|
10 Gbit/s |
- Any models of the S5700-X-LI series can set up a stack.
- A switch supports a maximum of two logical stack ports, and each logical stack port contains one or two stack member ports. Each switch can use a maximum of four service ports as stack member ports. When a logical stack port contains two stack member ports, the logical stack port can contain only stack member ports 1 and 2 or stack member ports 3 and 4.
|
S5700S-P-LI |
Two SFP optical ports |
- 1 m SFP+ passive high-speed copper cables
- 10 m SFP+ active high-speed copper cables
- 3 m and 10 m AOC cables
- 6GE stack optical module (SFP-6GE-LR) and optical fiber
- 0.5 m and 1.5 m SFP+ dedicated stack cables (supported in V200R011C10 and later versions)
|
- Using a 10 m SFP+ active high-speed copper: 5 Gbit/s
- Using other stack cable: 2.5 Gbit/s
|
- Any models of the S5700S-P-LI series can set up a stack.
- A switch supports a maximum of two logical stack ports, and each logical stack port contains one or two stack member ports. Each switch can use a maximum of two service ports as stack member ports.
|
S5700S-X-LI |
Four SFP+ optical ports |
- 1 m and 3 m SFP+ passive high-speed copper cables
- 5 m SFP+ passive high-speed copper cables (supported in V200R009 and later versions)
- 10 m SFP+ active high-speed copper cables
- 3 m and 10 m AOC cables
- 10GE SFP+ optical module and optical fiber
- 0.5 m and 1.5 m SFP+ dedicated stack cables (supported in V200R011C10 and later versions)
|
10 Gbit/s |
- Any models of the S5700S-X-LI series can set up a stack.
- A switch supports a maximum of two logical stack ports, and each logical stack port contains one or two stack member ports. Each switch can use a maximum of four service ports as stack member ports. When a logical stack port contains two stack member ports, the logical stack port can contain only stack member ports 1 and 2 or stack member ports 3 and 4.
Since V200R010, if stack member ports are connected using 1
m or 3 m SFP+ passive high-speed copper cables on S5700S-X-LI, their
working speed can be increased to 12 Gbit/s using the stack
port speed command. After their working speed is increased
to 12 Gbit/s, switches using these ports cannot set up a stack with
switches using ports with the working speed 10 Gbit/s.
|