< Home

S5735-L, S5735S-L, S5735S-L-M, S5735-S, and S5735S-S Service Port Stacking Support

  • For the cables that can be used as stack cables, see "Cables" in the Hardware Description. Using other cables may cause exceptions in the stack system, for example, frequent error-down events on stack ports.
  • Combo ports cannot function as stack member ports.
  • For stacking-supported service ports, some of them can be used as stack ports, whereas some can be used as ordinary service ports.
  • The number of stacked switches is recommended to be 2 to 9.
Table 1 Service port stacking support

Device Series

Port Supporting Stacking

Stack Cable

Rate of a Single Port

Remarks

S5735-L, S5735S-L, and S5735S-L-M

SFP+ optical port

For models without fan modules:

  • 1 m and 3 m SFP+ passive high-speed copper cables
  • 3 m and 10 m AOC cables
  • 10GE SFP+ optical module and optical fiber (a maximum transmission distance of 0.4 km)
  • 0.5 m and 1.5 m SFP+ dedicated stack cable

For models with fan modules:

  • 1 m and 3 m SFP+ passive high-speed copper cables
  • 3 m and 10 m AOC cables
  • 10GE SFP+ optical module and optical fiber
  • 0.5 m and 1.5 m SFP+ dedicated stack cable

10 Gbit/s

  • Any models of the S5735-L can set up a stack. Any models of the S5735S-L can set up a stack. Any models of the S5735S-L-M can set up a stack. The S5735S-L can set up a stack with the S5735S-L-M. The S5735-L cannot set up a stack with the S5735S-L and S5735S-L-M.
  • Ports of two different types on a switch can be configured as stack ports simultaneously, except 1 Gbit/s and 10 Gbit/s ports. Each logical stack interface can contain only ports of the same rate.
  • If uplink SFP optical ports on the front panel or SFP+ optical ports are used as stack ports, a switch supports a maximum of two logical stack ports, and each logical stack port supports at least one stack member port and at most four stack member ports. A switch supports a maximum of four stack member ports.
  • If electrical ports or downlink SFP optical ports on the front panel are used as stack ports, a switch supports a maximum of two logical stack ports, and each logical stack port supports at least one stack member port and at most eight stack member ports. A switch supports a maximum of 16 stack member ports.

Uplink SFP optical ports (1000BASE-X Ethernet optical ports) on the front panel

For models without fan modules:

  • 1 m and 3 m SFP+ passive high-speed copper cables
  • 3 m and 10 m AOC cables
  • 10GE SFP+ optical module and optical fiber (a maximum transmission distance of 0.4 km)
  • 0.5 m and 1.5 m SFP+ dedicated stack cable

For models with fan modules:

  • 1 m and 3 m SFP+ passive high-speed copper cables
  • 3 m and 10 m AOC cables
  • 10GE SFP+ optical module and optical fiber
  • 0.5 m and 1.5 m SFP+ dedicated stack cable

10 Gbit/s

Downlink SFP optical ports (100 or 1000BASE-X Ethernet optical ports) on the front panel

GE SFP optical module and optical fiber

1 Gbit/s

Electrical ports on the front panel

Category 5 or higher network cable

1 Gbit/s

S5735-S and S5735S-S

SFP+ optical port

  • 1 m and 3 m SFP+ passive high-speed copper cables
  • 3 m and 10 m AOC cables
  • 10GE SFP+ optical module and optical fiber
  • 0.5 m and 1.5 m SFP+ dedicated stack cable

10 Gbit/s

  • Any models of the S5735-S can set up a stack, and any models of the S5735S-S can set up a stack. The S5735-S cannot set up a stack with the S5735S-S.
  • Ports of two different types on a switch can be configured as stack ports simultaneously, except 1 Gbit/s and 10 Gbit/s ports. Each logical stack interface can contain only ports of the same rate.
  • If uplink SFP optical ports on the front panel or SFP+ optical ports are used as stack ports, a switch supports a maximum of two logical stack ports, and each logical stack port supports at least one stack member port and at most four stack member ports. A switch supports a maximum of four stack member ports.
  • If electrical ports or downlink SFP optical ports on the front panel are used as stack ports, a switch supports a maximum of two logical stack ports, and each logical stack port supports at least one stack member port and at most eight stack member ports. A switch supports a maximum of 16 stack member ports.

Uplink SFP optical ports (1000BASE-X Ethernet optical ports) on the front panel

  • 1 m and 3 m SFP+ passive high-speed copper cables
  • 3 m and 10 m AOC cables
  • 10GE SFP+ optical module and optical fiber
  • 0.5 m and 1.5 m SFP+ dedicated stack cable

10 Gbit/s

Downlink SFP optical ports (100 or 1000BASE-X Ethernet optical ports) on the front panel

GE SFP optical module and optical fiber

1 Gbit/s

Electrical ports on the front panel

Category 5 or higher network cable

1 Gbit/s

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >