Checking the Power Supply System
The power supply system must be ready before the installation. Table 1 describes the requirements for the power supply system of the S2700, S3700, S5700, and S6700 series switches.
Table 1 Power supply requirementsItem
|
Requirement
|
Input voltage
|
The input voltage must be within switch specifications. For details, see the Hardware Description.
|
Power outlets and power cables
|
- To use AC power outlets, switches must have built-in AC power supply units or pluggable AC power modules, and use AC power cables complying with local standards.
- To use an AC power distribution unit (PDU), switches must have built-in AC power supply units or pluggable AC power modules, and use C13 straight female to C14 straight male power cables.
- To use a DC power distribution box, switches must have built-in DC power supply units or pluggable DC power modules, and use DC power cables.
- The power cables and plugs delivered with a switch are for use with this switch only. Do not use them on other devices.
|
Circuit breaker of each channel
|
The rated current of a circuit breaker must be greater than the maximum input current of power modules.
|