The delay-measure one-way threshold command sets the alarm threshold for one-way frame delay measurement.
The undo delay-measure one-way threshold command cancels the configuration.
Parameter | Description | Value |
---|---|---|
threshold-value | Specifies the alarm threshold for one-way frame delay measurement. | The value is an integer that ranges from 1 to 4294967295, in microseconds. |
Usage Scenario
The delay-measure one-way threshold command sets an alarm threshold for one-way frame delay measurement between a MEP and an RMEP. When the one-way frame delay exceeds the alarm threshold, an alarm is generated.
Precautions
IEEE 802.1ag has two versions: IEEE 802.1ag Draft 7 and IEEE Standard 802.1ag-2007. This command can be used only on the device running IEEE Standard 802.1ag-2007.
This command is applicable to VLANs.
Before setting the alarm threshold, you must correctly configure the MD and MA.