The delay-measure two-way threshold command sets the alarm threshold for two-way frame delay measurement.
The undo delay-measure two-way threshold command cancels the configuration.
Parameter | Description | Value |
---|---|---|
threshold-value | Specifies the alarm threshold for two-way frame delay measurement. | The value is an integer that ranges from 1 to 4294967295, in microseconds. |
Usage Scenario
This command is applicable to VLANs. You can set the alarm threshold for two-way frame delay measurement on the MEP or RMEP. When the two-way delay exceeds the alarm threshold, an alarm is generated.
Precautions
IEEE 802.1ag has two versions: IEEE 802.1ag Draft 7 and IEEE Standard 802.1ag-2007. This command can be used only on the device running IEEE Standard 802.1ag-2007.
Before setting the alarm threshold, you must correctly configure the MD and MA.