The display built-in power command displays the built-in power supply status of switches with extended temperature range.
Only S5720I-28X-SI-AC and S5720I-28X-PWH-SI-AC support this command.
You can run the display built-in power command to check whether the built-in power supply status of switches with extended temperature range is normal.
If some member switches do not support this command, the system displays a prompt message.
# Display the built-in power supply status of switches with extended temperature range.
<HUAWEI> display built-in power
------------------------------------------------------------
Slot PowerID State
------------------------------------------------------------
1 PWR1 Normal
PWR2 Abnormal
2 PWR1 Normal
PWR2 Abnormal
------------------------------------------------------------
Info: Slot 0 does not support the command.
Item |
Description |
---|---|
Slot |
Slot ID. |
PowerID |
Power supply ID. |
State |
Power supply status:
|