Function

The display deception decoy status command displays the registration status of a DecoySensor on a Decoy.

Format

display deception decoy status

Parameters

None

Views

All views

Default Level

1: Monitoring level

Usage Guidelines

A DecoySensor initiates registration to a Decoy. If the registration succeeds:

  • The registration status changes from INIT to ALIVE.
  • The Decoy informs the DecoySensor of a port list for which the deception service is provided. Only the traffic whose destination ports in the list can be lured to the Decoy for further detection.

  • The DecoySensor and Decoy send heartbeat packets to each other every 5 seconds. If the DecoySensor does not receive heartbeat packets from the Decoy within 60 seconds, its registration status changes to INIT. If the Decoy does not receive heartbeat packets from the DecoySensor within 60 seconds, it sends a deregistration packet to the DecoySensor. After the DecoySensor receives the packet, its registration status changes to INIT.

Example

# Display the registration status of a DecoySensor on a Decoy.

<HUAWEI> display deception decoy status
 Decoy register status information:                
   Register status                                             : alive  
   Decoy select                                                : master    
   Online time                                                 : 37062(s) 
   Send heartbeat timeout                                      : 0(s)   
   Receive heartbeat timeout                                   : 5(s)   
 Decoy register port information:                           
   445       80        8080      443       22         
   3389      21        3306      6379  
Table 1 Description of the display deception decoy status command output

Item

Description

Decoy register status information

Registration status of a DecoySensor on a Decoy.

Register status

Registration status:
  • init: Unregistered
  • alive: Successfully registered

Decoy select

Currently connected Decoy

  • master: Active
  • backup: Standby

Online time

Duration of the connection to the Decoy.

Send heartbeat timeout

Period after the DecoySensor sent the last heartbeat packet, in seconds.

Receive Heartbeat timeout

Period after the DecoySensor received the last heartbeat packet, in seconds.

Decoy register port information

Port information of the deception service provided by the Decoy.

Decoy nonsupport port statistics

Port statistics not supported by the Decoy.