The display otdr capture history-record interface command displays historical Optical Time Domain Reflectometer (OTDR) test results on an interface.
Parameter | Description | Value |
---|---|---|
interface-type interface-number |
Specifies the type and number of an interface. |
- |
To view historical OTDR test results on a specified interface, run the display otdr capture history-record interface command. Each test result displays reflection distances of 16 fibres, and the command output can display the latest 10 OTDR test results at most. If the reflection distance of an optical fiber is 0, the optical module connected to the optical fiber does not support OTDR testing.
# Display historical OTDR test results on GE0/0/1.
<HUAWEI> display otdr capture history-record interface gigabitethernet 0/0/1 ------------------------------------------------------------------------------------------------- Index Reflections Distance(m) Time ------------------------------------------------------------------------------------------------- 0 2027 0 0 0 0 0 0 0 2019-12-31 14:34:03 0 0 0 0 0 0 0 0 1 2021 0 0 0 0 0 0 0 2019-12-26 20:14:05 0 0 0 0 0 0 0 0 2 2019 0 0 0 0 0 0 0 2019-12-26 20:14:04 0 0 0 0 0 0 0 0 3 2021 0 0 0 0 0 0 0 2019-12-26 20:14:03 0 0 0 0 0 0 0 0 4 2021 0 0 0 0 0 0 0 2019-12-25 20:14:03 0 0 0 0 0 0 0 0 5 2021 0 0 0 0 0 0 0 2019-12-24 17:15:08 0 0 0 0 0 0 0 0 6 2021 0 0 0 0 0 0 0 2019-12-24 15:26:08 0 0 0 0 0 0 0 0 7 2021 0 0 0 0 0 0 0 2019-12-23 11:22:38 0 0 0 0 0 0 0 0 8 2021 0 0 0 0 0 0 0 2019-12-23 10:46:55 0 0 0 0 0 0 0 0 9 2021 0 0 0 0 0 0 0 2019-12-23 09:33:48 0 0 0 0 0 0 0 0
Item |
Description |
---|---|
Index |
Sequence number of an OTDR test result. |
Reflections Distance(m) |
Reflection distance, in meters. |
Time |
Time when an OTDR test is performed. |