< Home

display transceiver diagnosis interface

Function

The display transceiver diagnosis interface command displays the diagnosis parameters of an optical module.

Format

display transceiver diagnosis interface [ interface-type interface-number ]

Parameters

Parameter

Description

Value

interface-type interface-number

Specifies the type and number of an interface.
  • interface-type specifies the interface type.

  • interface-number specifies the interface number.

-

Views

All views

Default Level

1: Monitoring level

Usage Guidelines

You can run the display transceiver diagnosis interface command to check the digital diagnostic monitoring (DMM) information about an optical module.

Example

# Display the diagnosis parameters of the optical module installed in GigabitEthernet0/0/4.

<HUAWEI> display transceiver diagnosis interface gigabitethernet 0/0/4
Port GigabitEthernet0/0/4 transceiver diagnostic information:
Parameter        Current     Low Alarm    High Alarm
  Type            Value      Threshold    Threshold    Status
-------------   ---------    ---------    ----------   --------
TxPower(dBm)    -4.64        0.00         0.00         abnormal
RxPower(dBm)    -4.37        33.00        0.00         abnormal
Current(mA)     7.42         0.00         0.00         abnormal
Temp.(ºC)       30.00        0.00         0.00         abnormal
Voltage(V)      3.28         0.00         8.19         normal
Table 1 Description of the display transceiver diagnosis interface command output

Item

Description

Parameter Type

Parameter type:
  • TxPower(dBm): indicates the transmission power of the optical module, in dBm.
  • RxPower(dBm): indicates the receiving power of the optical module, in dBm.
  • Current(mA): indicates the current of the optical module, in mA.
  • Temp.(ºC): indicates the temperature of the optical module, in degree Celsius.
  • Voltage(V): indicates the voltage of the optical module, in V.

Current Value

Current value of a parameter. lanei/Lanei indicates a physical channel. This information can be displayed after Current Value of TxPower(dBm), RxPower(dBm), and Current(mA) of the 40GE and 100GE interfaces.

Low Alarm Threshold

Lower alarm threshold of a parameter.

High Alarm Threshold

Upper alarm threshold of a parameter.

Status

Status of the optical module:
  • Normal: The value is within the normal range.
  • Abnormal: The value is not within the normal range.
  • –40: The power is low.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >