Function

The display y1731 test-info command displays information about test instances for Y.1731 statistics collection.

Only the S5720-HI, S5730-HI, S5731-H, S5731-S, S5731S-H, S5731S-S, S5732-H, S6720-HI, S6730-H, S6730S-H, S6730-S, and S6730S-S support this command.

Format

display y1731 test-info [ test-id test-id ]

Parameters

Parameter Description Value
test-id test-id Displays information about a specified test instance. The value is an integer ranging from 1 to 4294967295.

Views

All views

Default Level

1: Monitoring level

Usage Guidelines

To view information about test instances for Y.1731 statistics collection, run the display y1731 test-info command.

Example

# Display information about test instance 1 for Y.1731 statistics collection on a device.

<HUAWEI> display y1731 test-info test-id 1
-----------------------------------------------------------
 TestId 1 information:
-----------------------------------------------------------
 MD Name                      : md1
 MA Name                      : ma
 MEP ID                       : 1
 Local Mac                    : 0000-1382-4569
 Remote MEP ID                : 2
 Bind Mac                     : --
 Send Mac                     : --
 8021p                        : --
 Uplink 8021p                 : --
 Downlink 8021p               : --
 Single LM                    : disabled
 Single LM Interval           : --
 Single LM Count              : --
 Single LM Receive            : disabled
 OneWay DM                    : disabled
 OneWay DM Interval           : --
 OneWay DM Count              : --
 OneWay DM Packet Size        : --
 OneWay DM Receive            : disabled
 TwoWay DM                    : disabled
 TwoWay DM Interval           : --
 TwoWay DM Count              : --
 TwoWay DM Packet Size        : --
 TwoWay DM Receive            : disabled
 Single SLM                   : continual
 Single SLM Interval          : 10ms
 Single SLM SendingCount      : 10
 Single SLM SendTimeout       : 5s
 Single SLM Receive           : disabled
 Single SLM RecvTimeout       : --
Table 1 Description of the display y1731 test-info command output

Item

Description

TestId 1 information

Information about test instance 1.

MD Name

Name of the MD.

MA Name

Name of the MA.

MEP ID

MEP ID.

Local Mac

Local MAC address.

Remote MEP ID

RMEP ID.

Bind Mac

MAC address of the RMEP.

Send Mac

MAC address carried in frames.

8021p

802.1p priority value specified in a specified test instance.

To set the 802.1p priority value specified in a specified test instance, run the test-id command.

Uplink 8021p

Priority value of upstream packets.

The switch does not support this function.

Downlink 8021p

Priority value of downstream packets.

The switch does not support this function.

Single LM

Whether Y.1731 packet sending is enabled for single-ended frame LM.
  • enabled
  • disabled

To enable Y.1731 packet sending for single-ended frame LM, run the loss-measure single-ended send test-id or loss-measure single-ended continual send test-id command.

Single LM Interval

Interval at which Y.1731 packets are sent for single-ended frame LM.

To set the interval at which Y.1731 packets are sent for single-ended frame LM, run the loss-measure single-ended send test-id or loss-measure single-ended continual send test-id command.

Single LM Count

Number of Y.1731 packets that are to be sent for single-ended frame LM.

To set the number of Y.1731 packets sent for single-ended frame LM, run the loss-measure single-ended send test-id command.

Single LM Receive

Whether Y.1731 packet receiving is enabled for single-ended frame LM.
  • enabled
  • disabled

To enable SLM frame sending for single-ended SLM, run the loss-measure single-ended receive test-id command.

OneWay DM

Whether Y.1731 packet sending is enabled for one-way frame DM.
  • enabled
  • disabled

The switch does not support one-way frame delay measurement based on test instances.

OneWay DM Interval

Interval at which Y.1731 packets are sent for one-way frame DM.

The switch does not support one-way frame delay measurement based on test instances.

OneWay DM Count

Number of Y.1731 packets sent for one-way frame DM.

The switch does not support one-way frame delay measurement based on test instances.

OneWay DM Packet Size

Size of Y.1731 packets transmitted for one-way frame DM.

The switch does not support one-way frame delay measurement based on test instances.

OneWay DM Receive

Whether Y.1731 packet receiving is enabled for one-way frame DM.
  • enabled
  • disabled

The switch does not support one-way frame delay measurement based on test instances.

TwoWay DM

Whether Y.1731 packet sending is enabled for two-way frame DM.
  • enabled
  • disabled

To enable Y.1731 packet sending for two-way frame DM, run the delay-measure two-way send test-id or delay-measure two-way continual send test-id command.

TwoWay DM Interval

Interval at which Y.1731 packets are sent for two-way frame DM.

To set the interval at which Y.1731 packets are sent for two-way frame DM, run the delay-measure two-way send test-id or delay-measure two-way continual send test-id command.

TwoWay DM Count

Number of Y.1731 packets sent for two-way frame DM.

To set the number of Y.1731 packets sent for two-way frame DM, run the delay-measure two-way send test-id command.

TwoWay DM Packet Size

Size of Y.1731 packets transmitted for two-way frame DM.

To set the size of Y.1731 packets transmitted for two-way frame DM, run the delay-measure two-way send test-id or delay-measure two-way continual send test-id command.

TwoWay DM Receive

Whether Y.1731 packet receiving is enabled for two-way frame DM.
  • enabled
  • disabled

To enable Y.1731 packet receiving for two-way frame DM, run the delay-measure two-way receive test-id command.

Single SLM

Whether Y.1731 packet sending is enabled for single-ended SLM.
  • enabled
  • disabled

To enable Y.1731 packet sending for single-ended SLM, run the loss-measure single-ended-synthetic send or loss-measure single-ended-synthetic continual send command.

Single SLM Interval

Interval at which SLM frames are sent for single-ended SLM.

To set the interval at which SLM frames are sent for single-ended SLM, run the loss-measure single-ended-synthetic send or loss-measure single-ended-synthetic continual send command.

Single SLM SendingCount

Number of SLM frames to be sent for single-ended SLM within each measurement period.

To set the number of SLM frames to be sent for single-ended SLM within each measurement period, run the loss-measure single-ended-synthetic send or loss-measure single-ended-synthetic continual send command.

Single SLM SendTimeout

Timeout period for the transmit end to receive SLM frames.

To set the timeout period for the transmit end to receive SLM frames, run the loss-measure single-ended-synthetic send or loss-measure single-ended-synthetic continual send command.

Single SLM Receive

Whether SLM frame sending is enabled for single-ended SLM.
  • enabled
  • disabled

To enable SLM frame sending for single-ended SLM, run the loss-measure single-ended-synthetic receive command.

Single SLM RecvTimeout

Timeout period for the receive end to receive SLM frames.

To set the timeout period for the receive end to receive SLM frames, run the loss-measure single-ended-synthetic receive command.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >