Function

The monitor-period command sets the monitoring interval of an eMDI instance.

The undo monitor-period command restores the default monitoring interval of an eMDI instance.

By default, the monitoring interval of an eMDI instance is 60 seconds.

Format

monitor-period period-value

undo monitor-period [ period-value ]

Parameters

Parameter Description Value
period-value

Specifies the monitoring interval of an eMDI instance.

The value is of the enumerated type and can be set to 10, 30, or 60, in seconds.

Views

eMDI instance view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

When eMDI is used to monitor quality and demarcate faults of video or audio services, an eMDI instance obtains monitoring data from the device at a specified interval.

Precautions

After an eMDI instance is started, its monitoring interval cannot be modified. To modify the monitoring interval, run the stop command to stop the eMDI instance first.

Example

# Set the monitoring interval of eMDI instance 1 to 10 seconds.

<HUAWEI> system-view
[HUAWEI] emdi
[HUAWEI-emdi] emdi instance 1
[HUAWEI-emdi-instance-1] monitor-period 10