< Home

engine session timeout inactive

Function

The engine session timeout inactive command sets the inactive flow aging time of an ECA session.

The undo engine session timeout inactive command restores the default inactive flow aging time of an ECA session.

By default, the inactive flow aging time of an ECA session is 15 seconds.

Format

engine session timeout inactive time

undo engine session timeout inactive

Parameters

Parameter Description Value
time Specifies the inactive flow aging time of an ECA session. The value is an integer in the range from 1 to 300, in seconds. The default value is 15.

Views

System view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

After ECA is configured on a device, the ECA session flow table ages out after a certain period. The flow table that is aged out is encapsulated and then sent to the CIS server as metadata. Inactive flow aging of ECA requires the device to export statistics about the flows that persist for a short period. Once adding packets to a flow stops, the device exports flow statistics to conserve memory space.

Prerequisites

Before running this command, you must run the defence engine enable command to enable the IAE.

Example

# Set the inactive flow aging time of an ECA session to 10 seconds.

<HUAWEI> system-view
[HUAWEI] defence engine enable
[HUAWEI] engine session timeout active 10
Copyright © Huawei Technologies Co., Ltd.