fib threshold-alarm

Function

The fib threshold-alarm command enables the alarm function for IPv4 route prefix usage and sets the alarm threshold.

The undo fib threshold-alarm command restores the default alarm threshold.

By default, the alarm function for IPv4 route prefix usage is enabled. The upper alarm threshold is 85% and the lower alarm threshold is 75%.

Product

Support

S5720-EI, S5720-HI, S5730-HI, S5731-H, S5731-S, S5731S-H, S5731S-S, S5732-H, S6720-EI, S6720-HI, S6720S-EI, S6730-H, S6730S-H, S6730-S, and S6730S-S

Supported

S2720-EI, S5720I-SI, S5720-LI, S5735-L, S5735S-L, S5735S-L-M, S5720S-LI, S5720S-SI, S5720-SI, S5735-S, S5735S-S, S5735-S-I, S5730S-EI, S5730-SI, S6720-LI, S6720S-LI, S6720S-SI, and S6720-SI

Not supported

Format

fib threshold-alarm upper-limit upper-limit-value lower-limit lower-limit-value

undo fib threshold-alarm

Parameters

Parameter Description Value

upper-limit upper-limit-value

Sets the upper alarm threshold for IPv4 route prefix usage.

The value is an integer that ranges from 1 to 100, in percentage.

lower-limit lower-limit-value

Sets the lower alarm threshold for IPv4 route prefix usage.

The value is an integer that ranges from 1 to 100, in percentage.

Views

System view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

Overload of the IPv4 route prefix usage will cause entries unable to be delivered and result in a forwarding failure.
  • When the upper alarm threshold for IPv4 route prefix usage is smaller than 100%, an alarm is generated when the resource usage exceeds the upper alarm threshold or reaches 100%.
  • When the upper alarm threshold for IPv4 route prefix usage is set to 100%, an alarm is generated when the resource usage reaches 100%.

Precautions

In versions earlier than V200R019C00SPC300, the upper alarm threshold for the IPv4 route prefix usage can be greater than or equal to the lower alarm threshold. In V200R019C00SPC300 and later versions, the upper alarm threshold for the IPv4 route prefix usage must be greater than the lower alarm threshold. If the upper alarm threshold for the IPv4 route prefix usage is configured to be equal to the lower alarm threshold on a switch running a version earlier than V200R019C00SPC300, the configuration will be lost after the switch is upgraded to V200R019C00SPC300 or a later version, and the upper and lower alarm thresholds will be restored to the default settings.

Example

# Enable the alarm function for IPv4 route prefix usage and set the upper and lower alarm thresholds to 85% and 60% respectively.

<HUAWEI> system-view
[HUAWEI] fib threshold-alarm upper-limit 85 lower-limit 60
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >