< Home

loss-measure single-ended continual send test-id

Function

The loss-measure single-ended continual send test-id command enables single-ended frame loss measurement based on the test instance.

The undo loss-measure single-ended continual send test-id command disables on-demand single-ended frame loss measurement.

By default, on-demand single-ended frame loss measurement is disabled.

Only the S5730-HI, S5731-H, S5731-S, S5731S-H, S5731S-S, S5732-H, S6720-HI, S6730-H, S6730S-H, S6730-S, and S6730S-S support this command.

Format

loss-measure single-ended continual send test-id test-id interval { 1000 | 10000 | 30000 }

undo loss-measure single-ended continual send [ test-id test-id ]

Parameters

Parameter Description Value
test-idtest-id Specifies the ID of a test instance. The value is an integer in the range from 1 to 4294967295.
interval Specifies the interval at which LMMs are sent. The value is 1000, 10000, or 30000, in milliseconds.

Views

MA view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

Statistics based on a test instance are mainly used in the P2MP scenario. You can run this command to collect non-stop packet loss statistics.

Prerequisites

The test-id test-id command has been run in the MA view to create a test instance.

Example

# Enable single-ended frame loss measurement based on test instance 1 in the VLAN scenario and set the interval to 30 seconds.

<HUAWEI> system-view
[HUAWEI] cfm enable
[HUAWEI] cfm md md1
[HUAWEI-md-md1] ma ma1
[HUAWEI-md-md1-ma-ma1] map vlan 10
[HUAWEI-md-md1-ma-ma1] loss-measure single-ended continual send test-id 1 interval 30000
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >