< Home

loss-measure single-ended receive test-id

Function

The loss-measure single-ended receive test-id command enables the remote device to receive LMMs based on the test instance to implement single-ended frame loss measurement.

The undo loss-measure single-ended receive test-id command disables the remote device from receiving LMMs based on the test instance.

By default, the remote device is disabled from receiving LMMs in an MA.

Only the S5730-HI, S5731-H, S5731-S, S5731S-H, S5731S-S, S5732-H, S6720-HI, S6730-H, S6730S-H, S6730-S, and S6730S-S support this command.

Format

loss-measure single-ended receive test-id test-id

undo loss-measure single-ended receive [ test-id test-id ]

Parameters

Parameter Description Value
test-id Specifies the ID of a test instance. The value is an integer in the range from 1 to 4294967295.

Views

MA view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

Statistics based on a test instance are mainly used in the P2MP scenario. When the packet loss rate is detected on a link to evaluate the link performance, you can run this command to enable the remote device to receive LMMs.

Prerequisites

The test-id test-id command has been run in the MA view to create a test instance.

Example

# Configure the remote device to receive LMMs based on the test instance.

<HUAWEI> system-view
[HUAWEI] cfm enable
[HUAWEI] cfm md md1
[HUAWEI-md-md1] ma ma1
[HUAWEI-md-md1-ma-ma1] map vlan 10
[HUAWEI-md-md1-ma-ma1] loss-measure single-ended receive test-id 1
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >