< Home

loss-measure single-ended send test-id

Function

The loss-measure single-ended send test-id command enables single-ended frame loss measurement based on the test instance.

By default, single-ended frame loss measurement based on the test instance is disabled.

Only the S5730-HI, S5731-H, S5731-S, S5731S-H, S5731S-S, S5732-H, S6720-HI, S6730-H, S6730S-H, S6730-S, and S6730S-S support this command.

Format

loss-measure single-ended send test-id test-id interval { 1000 | 10000 } count count-value

Parameters

Parameter Description Value
test-id Specifies the ID of a test instance. The value is an integer in the range from 1 to 4294967295.
interval Specifies the interval at which LMMs are sent. The value is 1000 or 10000, in milliseconds.
count count-value Specifies the single-ended frame loss measurement count. The value is an integer in the range from 1 to 60.

Views

MA view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

Statistics collection based on the test instance is applicable to the P2MP scenario. You can run this command to check the packet loss on the link periodically or once only.

Prerequisites

The test-id test-id command has been run in the MA view to create a test instance.

Example

# In the VLAN scenario, enable single-ended frame loss measurement based on the test instance 1 and set the measurement interval to 10 seconds and measurement count to 60 times.

<HUAWEI> system-view
[HUAWEI] cfm enable
[HUAWEI] cfm md md1
[HUAWEI-md-md1] ma ma1
[HUAWEI-md-md1-ma-ma1] map vlan 10
[HUAWEI-md-md1-ma-ma1] loss-measure single-ended send test-id 1 interval 10000 count 60
Copyright © Huawei Technologies Co., Ltd.