< Home

mask manual-clear alarm

Function

The mask manual-clear alarm command prevents manually cleared active alarms from being reported repeatedly.

The undo mask manual-clear alarm command restores the default configuration.

By default, active alarms are reported repeatedly after being manually cleared.

Format

mask manual-clear alarm

undo mask manual-clear alarm

Parameters

None

Views

Alarm management view

Default Level

3: Management level

Usage Guidelines

Usage Scenario

By default, after the clear alarm active command or MIB table hwAlarmActiveTable is used to manually clear active alarms, active alarms are reported repeatedly when being generated again. To prevent manually cleared active alarms from being reported repeatedly, run the mask manual-clear alarm command.

After the mask manual-clear alarm command is executed and then the clear alarm active command or MIB table hwAlarmActiveTable is used, cleared active alarms will not be reported repeatedly before clear alarms of active alarms are reported. To view all the active alarms that are not reported repeatedly, run the display alarm manual-clear command.

Precautions

Before the mask manual-clear alarm command is executed, the active alarms manually cleared using the clear alarm active command or MIB table hwAlarmActiveTable will be reported repeatedly.

Example

# Prevent manually cleared active alarms from being reported repeatedly.

<HUAWEI> system-view
[HUAWEI] alarm
[HUAWEI-alarm] mask manual-clear alarm
Copyright © Huawei Technologies Co., Ltd.