Function

The min-echo-rx-interval command configures the minimum interval for receiving BFD packets of a BFD session supporting the BFD echo function.

The undo min-echo-rx-interval command restores the default minimum interval.

By default, the minimum interval is 1000 ms.

Format

min-echo-rx-interval interval

undo min-echo-rx-interval

Parameters

Parameter

Description

Value

interval

Specifies the minimum interval for receiving BFD packets of a BFD session supporting the BFD echo function.

The value is an integer that ranges from 100 to 1000, in milliseconds.
  • After the set service-mode enhanced command is configured on the S5720-HI, S5730-HI, S5731-H, S5731-S, S5731S-H, S5731S-S, and S6720-HI, the value ranges from 3 to 1000.
  • After the set service-mode enhanced-bfd command is configured on the S5732-H, S6730-H, S6730S-H, S6730-S, and S6730S-S, the value ranges from 3 to 1000.

Views

BFD session view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

After creating a BFD session supporting the BFD echo function, you can set the minimum interval for receiving BFD packets of a BFD session supporting the BFD echo function.

Prerequisites

A BFD session supporting the echo function has been configured using the bfd one-arm-echo command.

Example

# Set the minimum interval for receiving BFD packets of a BFD session supporting the BFD echo function to 100 ms.

<HUAWEI> system-view
[HUAWEI] bfd test
[HUAWEI-bfd-session-test] min-echo-rx-interval 100