The oam-bind efm interface efm interface command enables bidirectional fault notification between EFM modules.
The undo oam-bind efm interface efm interface command cancels the configuration.
By default, bidirectional transmission of information about a fault between EFM OAM sessions is not configured.
oam-bind efm interface interface-type interface-number efm interface interface-type interface-number
undo oam-bind efm interface interface-type interface-number efm interface interface-type interface-number
Parameter | Description | Value |
---|---|---|
interface-type interface-number | Specifies the type and the number of an interface configured with bidirectional fault notification between EFM modules.
|
- |
Usage Scenario
If EFM is deployed at both sides of a device, associate EFM modules on the device to ensure reliable service transmission.
Association between EFM and EFM is bidirectional. EFM modules notify each other of faults.
Choose the preceding commands in different scenarios according to Table 1.
Scenario |
Configuration Solution 1 |
Configuration Solution 2 |
---|---|---|
Bidirectional fault notification between EFM modules | Run the oam-bind efm interface efm interface command. |
Use the following commands:
|
Unidirectional fault notification between EFM sessions | Choose either of the following commands based on the transmission
direction:
|
None |
Prerequisites
EFM OAM has been enabled on specified interfaces.
Two EFM OAM sessions have been associated with each other. When an EFM OAM session is associated with another EFM OAM session, the EFM OAM session cannot be associated with other EFM OAM sessions.