The oam-bind ingress bfd-session trigger if-down egress interface command enables a BFD session to report faults to an interface.
The undo oam-bind ingress bfd-session trigger if-down egress interface command disables a BFD session from reporting faults to an interface.
By default, a BFD session is not enabled to report faults to an interface.
Only the S5720-EI, S5720-HI, S5730-HI, S5731-H, S5731-S, S5731S-H, S5731S-S, S5732-H, S6720-EI, S6720-HI, S6720S-EI, S6730-H, S6730S-H, S6730-S, and S6730S-S support this command.
oam-bind ingress bfd-session bfd-session-id trigger if-down egress interface interface-type interface-number
undo oam-bind ingress bfd-session bfd-session-id trigger if-down egress interface interface-type interface-number
Parameter |
Description |
Value |
---|---|---|
bfd-session bfd-session-id |
Specifies the local discriminator. |
The value is an integer that ranges from 1 to 8191. |
trigger if-down |
Indicates that an interface goes Down when the BFD session associated with the interface detects a fault. |
- |
interface-type interface-number |
Specifies the type and number of the interface bound to
a BFD session.
|
- |
Usage Scenario
To enable a BFD session to report faults to an interface, run the oam-bind ingress bfd-session trigger if-down egress interface command.
Precautions
Before configuring a BFD session to report faults to an interface, pay attention to the following points:
A BFD session has been created and its status is Up.
The BFD session is a static BFD session.
The BFD session and the interface are associated with each other. That is, after an interface is associated with BFD session 1, the interface cannot be associated with other BFD sessions. Similarly, BFD session 1 cannot be associated with other interfaces.
The ingress BFD session reports faults to the egress interface.