The protect-mode command specifies the PW redundancy mode of a PW protection group.
The undo protect-mode command cancels the PW redundancy mode of a PW protection group.
By default, a PW protection group does not have a PW redundancy mode.
Parameter | Description | Value |
---|---|---|
pw-redundancy master | Specifies the PW redundancy mode of a PW protection group as master/slave. |
- |
Usage Scenario
You can configure PW protection groups to protect PW pairs of a VSI.
In the scenarios, in which the active/standby PWs cannot be determined based on the signaling sent by the remote end, you can create a PW protection group on the UPE, and specify the PW redundancy mode of the group as master/slave. The local UPE determines the active/standby PWs based on the priorities configured using the peer preference command.
When the mode of the group is master/slave, the local UPE does not determine the active/standby PWs based on the signaling sent by the remote end.
Prerequisites
The PW protection group has been configured using the protect-group command.
Precautions
A static hub PW and a static spoke PW cannot be added to the same protection group.
After a PW protection group is configured, you must specify the PW redundancy mode before configuring other parameters. Deleting the PW redundancy mode of a PW protection group will clear all the configurations of the group.