The ptp asymmetry-correction command sets the delay offset value to ensure accurate time synchronization.
The undo ptp asymmetry-correction command restores the default delay offset.
By default, the asymmetry correction value of the PTP packet sent from the interface is not configured.
ptp asymmetry-correction { positive | negative } asymmetry-correction
undo ptp asymmetry-correction
Parameter |
Description |
Value |
---|---|---|
positive asymmetry-correction |
Indicates the positive asymmetry correction value. |
The value is an integer that ranges from 0 to 2000000, in ns. The default value is 0. |
negative asymmetry-correction |
Indicates the negative asymmetry correction value. |
The value is an integer that ranges from 0 to 2000000, in ns. The default value is 0. |
In case of path delay calculation, PTP measures the packet sending path only and considers the delays for sending and receiving packets as the same by default.
If the two delays are different or asymmetric, you need to configure an asymmetry correction value. In this case, the device automatically considers the asymmetry correction value in the path delay calculation complying with the Pdelay or Delay measurement mechanism.