The receiving-admindown trigger if-down command enables a local device to instruct the interface protocol to go down immediately after receiving an admindown packet.
The undo receiving-admindown trigger if-down command disables a local device from instructing the interface protocol to go down immediately after receiving an admindown packet.
By default, the local device is disabled from instructing the interface protocol to go down immediately after receiving an admindown packet.
After the process-interface-status command associates a BFD session with the status of an interface bound to the BFD session, a local device does not instruct the interface protocol to go down after the device receives an admindown packet. To enable an immediate notification, run the receiving-admindown trigger if-down command.
Prerequisites
The BFD session status has been associated with the status of the interface bound to the BFD session using the process-interface-status command.
Precautions
# Enable the local device to instruct the interface protocol to go down immediately after receiving an admindown packet.
<HUAWEI> system-view [HUAWEI] bfd test bind peer-ip default-ip interface gigabitethernet0/0/1 [HUAWEI-bfd-session-test] process-interface-status [HUAWEI-bfd-session-test] receiving-admindown trigger if-down