< Home

reset fault-management (upgrade-compatible command)

Function

The reset fault-management command clears all alarm messages.

Format

reset fault-management { active-alarm | event } [ sequence-number sequence-number ]

Parameters

Parameter Description Value
active-alarm Clears information about active alarms. -
event Clears event information. -
sequence-number sequence-number Specifies the number of an alarm message. The value is an integer ranging from 0 to 2147483647. If the value is 0, it indicates that all alarm messages are cleared.

Views

System view

Default Level

3: Management level

Usage Guidelines

If sequence-number is not specified, the system clears all the alarm messages on the device.

After this command is run, all alarm messages on a device are cleared and cannot be restored.

Example

# Clear all active alarm messages.

<HUAWEI> system-view
[HUAWEI] reset fault-management active-alarm
Copyright © Huawei Technologies Co., Ltd.