The set fan speed auto min-speed command configures the minimum fan speed in automatic fan speed adjustment mode.
The undo set fan speed auto min-speed command restores the default minimum fan speed in automatic fan speed adjustment mode.
By default, the minimum fan speed in automatic fan speed adjustment mode is not configured.
The following switches do not support this command:
If one of the preceding switches can set up a stack with other switch models that support this command, this switch also supports this command so that this command can be executed and delivered in the stack.
set fan speed auto min-speed value [ slot slot-id | all ]
undo set fan speed auto min-speed [ slot slot-id | all ]
Parameter | Description | Value |
---|---|---|
value |
Sets the percentage of the minimum fan speed. For example, if this parameter is set to 35, the minimum fan speed in automatic fan speed adjustment mode is 35% of the full fan speed. |
The value is an integer that ranges from 1 to 100. |
slot slot-id |
Specifies a slot ID. If this parameter is not specified, the minimum fan speed in automatic fan speed adjustment mode is configured for the fans on the master switch. |
The value depends on the device configuration. |
all |
Specifies all slots. |
- |
Usage Scenario
The fan speed affects the device temperature. When the device temperature is high, increase the fan speed to lower the device temperature. When the device temperature is low, reduce the fan speed to save energy. A proper fan speed ensures stable device operation. By default, fans run in automatic fan speed adjustment mode. In this mode, the system adjusts the fan speed when detecting that the device temperature increases or decreases. To control the fan speed in a timely manner, run the set fan speed auto min-speed command to configure the minimum fan speed in automatic speed adjustment mode.
Precautions
# Set the minimum fan speed in automatic fan speed adjustment mode to 20% of the full fan speed.
<HUAWEI> system-view [HUAWEI] set fan speed auto min-speed 20 Info: The configuration is successful and takes effect only when the specified value is greater than the value calculated based on the intelligent fan speed adjustment policy.