< Home

shutdown interface

Function

The shutdown interface command disables an AS port.

The undo shutdown interface command enables an AS port.

By default, an interface is enabled.

This command can only be executed on a parent switch.

Format

shutdown interface interface-type interface-number

undo shutdown interface interface-type interface-number

Parameters

Parameter Description Value
interface-type interface-number
Specifies the interface type and number.
  • interface-type specifies the interface type. The interface type cannot be an Eth-Trunk interface.
  • interface-number specifies the interface number.

-

Views

AS view

Default Level

3: Management level

Usage Guidelines

Usage Scenario

You can run the shutdown interface command to disable an AS port.

Precautions

Running this command can disable only an AS downlink port but not an AS uplink port. If an uplink port has been configured as a downlink fabric port, this port can be disabled.

If the version of an AS is inconsistent with that of the parent, the shutdown interface and undo shutdown interface commands do not take effect on the ports of this AS.

If an AS is configured in the independent mode, the shutdown interface and undo shutdown interface commands do not take effect on the ports of this AS.

Example

# Disable an AS port.

<HUAWEI> system-view
[HUAWEI] uni-mng
[HUAWEI-um] as name as1
[HUAWEI-um-as-as1] shutdown interface gigabitethernet 0/0/1
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >