The transceiver phony-alarm-disable command disables the alarm function for non-Huawei-certified switch optical modules.
The undo transceiver phony-alarm-disable command enables the alarm function for non-Huawei-certified switch optical modules.
By default, the alarm function is enabled for non-Huawei-certified switch optical modules.
Non-Huawei-certified switch optical modules may fail to work normally. If non-Huawei-certified switch optical modules are used on devices produced since July 1, 2013 (January 1, 2016 for QSFP+ 40GE optical modules), the devices generate a large number of alarms to prompt users to replace these optical modules with Huawei-certified switch optical modules. However, vendor information of optical modules early delivered from Huawei may not be recorded. Therefore, non-Huawei-certified switch optical module alarms are generated. These optical modules can still be used to protect customer investment. In this case, you can disable the alarm function for non-Huawei-certified switch optical modules.
# Disable the alarm function for non-Huawei-certified switch optical modules.
<HUAWEI> system-view [HUAWEI] transceiver phony-alarm-disable Info:Transceiver-phony-alarm disable.
# Enable the alarm function for non-Huawei-certified switch optical modules.
<HUAWEI> system-view [HUAWEI] undo transceiver phony-alarm-disable Info:Transceiver-phony-alarm enable.