The trap-threshold error-statistics command sets the alarm threshold for error packets and alarm interval.
The undo trap-threshold error-statistics command restores the default alarm threshold for error packets and default alarm interval.
By default, the alarm threshold for error packets is 3 and the alarm interval is 10 seconds.
trap-threshold error-statistics threshold-value interval interval-value
undo trap-threshold error-statistics
Parameter |
Description |
Value |
---|---|---|
threshold-value |
Sets the alarm threshold for error packets. |
The value is an integer that ranges from 1 to 65535. NOTE:
The value should not be greater than the alarm threshold for error packets that cause the interface status to change to Error-Down configured by the error-down-threshold error-statistics command. |
interval interval-value |
Sets the interval for reporting alarms for error packets. |
The value is an integer that ranges from 10 to 65535, in seconds. |
Ethernet interface view, GE interface view, XGE interface view, MultiGE interface view, 25GE interface view, 40GE interface view, 100GE interface view, port group view