< Home

user-sync

Function

The user-sync command enables user information synchronization.

The undo user-sync command disables user information synchronization.

By default, user information synchronization is disabled.

Format

user-sync [ interval interval-period | max-times times ] *

undo user-sync

Parameters

Parameter Description Value
interval interval-period

Specifies the user information synchronization interval.

The value is an integer that ranges from 30 to 65535, in seconds. The default value is 300.
max-times times

Specifies the maximum number of user information synchronization failures.

The value is an integer that ranges from 2 to 255. The default value is 3.

Views

Portal server template view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

If communication is interrupted because the network between the device and Portal server is disconnected or the Portal server is faulty, online Portal authentication users cannot go offline. Therefore, user information on the device and on the Portal server may be inconsistent and accounting may be inaccurate.

The user-sync command enables user information synchronization so that user information on the device and Portal server is synchronized at intervals to ensure user information consistency.

During information synchronization, the device does not disconnect the user immediately after detecting that the device has certain user information while the server does not have such information. Instead, the device disconnects the user when the maximum number of user information synchronization failures is reached.

Precautions

If users go online during the keepalive interval of the Portal server, the Portal server does not have their entries. After the Portal server goes Up and starts synchronizing user information, the device does not disconnect these users even if synchronization fails. The device retails these users until next time these users go online and performs Portal authentication, ensuring good user experience.

The value of interval-period*times configured on the device must be greater than the interval for the Portal server to send synchronization packets. Otherwise, the device forces users offline when it cannot receive any synchronization packet from the Portal server after the maximum failure number is reached.

Example

# Enable user information synchronization in the Portal server template abc, set the interval for user information synchronization to 100s, and set the maximum number of synchronization failures to 5.

<HUAWEI> system-view
[HUAWEI] web-auth-server abc
[HUAWEI-web-auth-server-abc] user-sync interval 100 max-times 5
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.