ARP_1.3.6.1.4.1.2011.5.25.123.2.34 hwEthernetARPDynamicEntryExceedAlarm

Trap Buffer Description

The number of dynamic ARP entries exceeds the specification. (EntPhysicalIndex=[EntPhysicalIndex], Slot name=[SlotName], Specs=[Specs], Number of dynamic ARP entries=[DynEntries]).

The number of dynamic ARP entries exceeds the specification.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwARPDynEntryExceed

Trap OID

1.3.6.1.4.1.2011.5.25.123.2.34

MIB

HUAWEI-ETHARP-MIB

Alarm ID

0x00F102d7

Alarm Name

ARP_DYNAMIC_ENTRY_SPECS_EXCEED

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Raise

Match trap

ARP_1.3.6.1.4.1.2011.5.25.123.2.35 hwEthernetARPDynamicEntryResumeAlarm

Trap Buffer Parameters

Parameter Description

EntPhysicalIndex

Indicates the index of the physical entity.

SlotName

Indicates the board name.

Specs

Indicates the maximum number of ARP dynamic entries.

DynEntries

Indicates the number of dynamic ARP entries.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.123.1.39.1

hwEthernetARPEntrySpecValue

-

1.3.6.1.4.1.2011.5.25.123.1.39.2

hwEthernetARPEntrySpecDynamicNumber

-

Impact on the System

There are too many dynamic ARP entries on the board. Therefore, new ARP entries fail to be learned, and services may be interrupted.

After this alarm is reported, power-off or resetting cannot be performed. Otherwise, resources may be re-allocated and services may be affected.

Possible Causes

The number of ARP entries learned by a device board exceeds the specification.

Procedure

1. Run the display arp all command to determine the interfaces that have a large number of ARP entries. For these interfaces, run the display arp interface command to view the ARP entries and check whether these ARP entries are required by users.

  • If these ARP entries are required by users, go to Step 3.
  • If these ARP entries are not required by users, run the reset arp command to manually clear some ARP entries with the prerequisite that services are not affected. In this case, go to Step 2.

2. Run the display arp statistics command to check whether the number of ARP entries on the device continues to increase abnormally.

  • If the number of ARP entries does not keep increasing, go to Step 4.
  • If the number of ARP entries keeps increasing, go to Step 3.

3. Collect alarm and configuration information, and contact Huawei technical support personnel.

4. End.