BFD_1.3.6.1.4.1.2011.5.25.38.3.15 hwBfdBitErrorDetectSessReachLimit

Trap Buffer Description

The bit-error-detection session number in all the IO boards has reached the limit, the new bit-error-detection session can not be created. (TotalBitErrorDetectionSessionLimit=[TotalBitErrorDetectSessionLimit])

The number of all the BFD bit-error-detection sessions set up on interface boards reached the PAF upper limit and no more bit-error-detection session can be set up.

Trap Attributes

Trap Attribute Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

BfdBitErrorDetectSessReachLimit

Trap OID

1.3.6.1.4.1.2011.5.25.38.3.15

MIB

HUAWEI-BFD-MIB

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Name

This is an event trap and does not involve alarm name.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

-

Trap Buffer Parameters

Parameter Description

TotalBitErrorDetectSessionLimit

Indicates the upper limit of global BFD bit-error-detection sessions.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.38.1.20

hwBfdBitErrorDetectSessLimitNumber

-

Impact on the System

Services will not be affected.

After the alarm is generated, do not power off or reset the device; otherwise, resources will be reassigned, and services will be affected.

Possible Causes

New BFD configurations were still committed when the number of global BFD bit-error-detection sessions reached the upper limit.

Procedure

1. Stop configuring BFD bit-error-detection sessions.

2. Delete unwanted BFD bit-error-detection sessions.

3. Collect log information and configuration information, and then contact technical support personnel.

4. End.

Copyright © Huawei Technologies Co., Ltd.