BGP_1.3.6.1.4.1.2011.5.25.177.1.3.35 bgpPeerAfPerRouteExceed

Trap Buffer Description

The routes number of the specified type received from peers in a BGP address family reached the maximum value. (Address Family=[AddressFamily], RouteType=[RouteType], MaxRouteNumber=[RouteLimitNum], BGP instance name=[InstanceName])

The routes number of the specified type received from peers in a BGP address family reached the maximum value.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwBgpPeerAddrFamilyPerRouteExceed

Trap OID

1.3.6.1.4.1.2011.5.25.177.1.3.35

MIB

HUAWEI-BGP-VPN-MIB

Alarm ID

0x00f103ba

Alarm Name

hwBgpPeerAddrFamilyPerRouteExceed

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

BGP_1.3.6.1.4.1.2011.5.25.177.1.3.36 bgpPeerAfPerRouteExceedClear

Trap Buffer Parameters

Parameter Description

AddressFamily

Address family.

RouteType

Route type.

RouteLimitNum

The maximum route number.

InstanceName

BGP instance name. "-" indicates the default BGP instance, and other values indicate multiple instances.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.177.1.2.2.1.5

hwBgpVrfAddressFamily

hwBgpVrfRouteType

hwBgpVrfInstName

hwBgpVrfAddressFamily

1.3.6.1.4.1.2011.5.25.177.1.2.1.5

hwBgpRouteType

-

1.3.6.1.4.1.2011.5.25.177.1.2.1.3

hwBgpRouteMaxNum

-

1.3.6.1.4.1.2011.5.25.177.1.5.1.1.1

hwBgpProcessName

hwBgpProcessName

Impact on the System

The routes number of the specified type received from peers in the address family has reached the specification, and no more new routes of specified type can be received.

Possible Causes

The routes number of the specified type received from peers in a BGP address family reached the maximum value.

Procedure

1. Reduce the routes number of specified type sent by the peer end. Then, check whether the alarm is cleared. That is, check whether the matching clear alarm (hwBgpPeerAddrFamilyPerRouteExceedClear) is generated. - If the clear alarm is generated, go to Step 3. - If the clear alarm is not generated, go to Step 2. 2. Collect alarm information and configuration information, and then contact technical support personnel. 3. End.