BRASAAA_1.3.6.1.4.1.2011.5.2.2.2.0.37 hwAAAAccessUserResourceOrCpuAlarm

Trap Buffer Description

The resource of users or cpu usage on the device reached the upper threshold. (Slot=[slotId],Cpu usage=[cpuUsage],User resource usage=[usrResUsage])

The resource of users or cpu usage on the device reached the upper threshold.

In VS mode, this trap is supported only by the admin VS.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwAAAAccessUserResourceOrCpuAlarm

Trap OID

1.3.6.1.4.1.2011.5.2.2.2.0.37

MIB

HUAWEI-AAA-MIB

Alarm ID

0x0aeb2036

Alarm Name

hwAAAAccessUserResourceOrCpuAlarm

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Raise

Match trap

BRASAAA_1.3.6.1.4.1.2011.5.2.2.2.0.38 hwAAAAccessUserResourceOrCpuResume

Trap Buffer Parameters

Parameter Description

slotId

SlotId

cpuUsage

Cpu usage

usrResUsage

User resource usage

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.2.2.1.4

hwUserSlot

-

1.3.6.1.4.1.2011.5.2.2.1.22

hwAAACpuUsage

-

1.3.6.1.4.1.2011.5.2.2.1.23

hwAAAUserResourceUsage

-

Impact on the System

If the problem is not resolved, the user resource usage or CPU usage reaches the specified upper limit, and new user access requests are denied.

Possible Causes

Cause 1: The user resource usage or CPU usage reached the upper limit when excessive users were online.

Cause 2: The specified upper limit was too small.

Procedure

1. Run the display this command in the system view to check whether the upper limit configured using the access-user exhaust threshold-alarm { main-resource-usage | slot-resource-usage | main-cpu-usage | slot-cpu-usage } upper-limit upper-limit lower-limit lower-limit command is too small.

  • If the upper limit is too small, go to Step 2.
  • If the upper limit is not too small, go to Step 3.

2.Run the access-user exhaust threshold-alarm command in the system view to reconfigure an alarm threshold for the user resource or CPU usage (upper-limit). Then check whether a clear alarm is generated.

  • If a clear alarm is generated, go to Step 5.
  • If no clear alarm is generated, go to Step 4.

3.Run the display access-user [ slot slot-id ] command in any view to check whether the value of the Total users field is close to the maximum number of users supported on the device.

  • If the value is close to the maximum number of users supported on the device, add an interface board to the device.
  • If the value is not close to the maximum number of users supported on the device, go to Step 4.

4.Collect alarm, log, and configuration information, and contact Huawei technical support personnel.

5.End.