The number of sessions reached the upper limit of the device. (SessionUpperLimitThreshold=[threshold])
The number of sessions reached the upper limit of the device.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Warning |
Mnemonic Code |
hwAAAOnlineSessoinUpperLimitAlarm |
Trap OID |
1.3.6.1.4.1.2011.5.2.2.2.0.43 |
MIB |
HUAWEI-AAA-MIB |
Alarm ID |
0x0aeb2005 |
Alarm Name |
hwAAAOnlineSessoinUpperLimitAlarm |
Alarm Type |
communicationsAlarm |
Raise or Clear |
Raise |
Match trap |
BRASAAA_1.3.6.1.4.1.2011.5.2.2.2.0.44 hwAAAOnlineSessoinUpperLimitResume |
Parameter | Description |
---|---|
threshold |
Upper threshold for online sessions on the device, determined by configuration, in percentage |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.2.2.1.26 |
hwAAASessionUpperLimitThreshold |
- |
1.Run the display this command in the system view to display user-stack warning-threshold, and check whether the upper threshold is too low.
2.If the upper threshold is too low, reset it, and then go to Step 6.
3.Run the display access term statistics userstack command in the system view to check the number of current sessions. If the number of current sessions is close to the maximum number of users that the device can support, add an interface board.
4.Then, check whether the trap is cleared.
5.Collect trap, log, and configuration information, and contact technical support personnel.
6.End.