BRASAAA_1.3.6.1.4.1.2011.5.2.2.2.0.5 hwUserMaxNum

Trap Buffer Description

The number of user resources on the board or the device reached the threshold. (Type=[type],Slot=[slotid],MaxUserThreshold=[threshold])

The number of user resources on the board reached the threshold.

In VS mode, this trap is supported only by the admin VS.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwUserMaxNum

Trap OID

1.3.6.1.4.1.2011.5.2.2.2.0.5

MIB

HUAWEI-AAA-MIB

Alarm ID

0x0aeb202c

Alarm Name

hwUserMaxNum

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Raise

Match trap

BRASAAA_1.3.6.1.4.1.2011.5.2.2.2.0.60 hwUserMaxNumResume

Trap Buffer Parameters

Parameter Description

type

User type

slotid

ID of the slot through which users go online. If the alarm type is set to 3, or 4, the slot value is 255.

threshold

Threshold of the number of users, in percentage. For example, if the value is 80, the user resource threshold is 80%.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.2.2.1.7

hwMaxUserThresholdType

-

1.3.6.1.4.1.2011.5.2.2.1.4

hwUserSlot

-

1.3.6.1.4.1.2011.5.2.2.1.5

hwUserSlotMaxNumThreshold

-

Impact on the System

When the number of access users reaches the threshold, subsequent users may fail to go online.

Possible Causes

Cause 1:The number of access users exceeded the threshold.

Cause 2:The threshold was set too small.

Procedure

1.In the system view, run the display current-configuration command to check whether the user resource threshold (dhcp-user-slot-warning-threshold/ppp-user-slot-warning-threshold/dhcp-user-warning-threshold/ppp-user-warning-threshold) is set too small.

  • If the threshold is set too small, re-configure it.
  • If the threshold is properly set, go to Step 2.

2.If the number of users on a board exceeds the threshold, run the display access-user slot slot-id command in the system view to check whether the number of users reaches the threshold of the board. If so, replace it with a new one that can accommodate more user resources.

3.If the number of global user resources exceeds the threshold, run the display access-user command in the system view to check whether the number of current users reaches the upper threshold of the device. If so, add an interface board or go to Step 5.

4.Check whether the alarm is cleared.

  • If so, go to Step 6.
  • If not, go to Step 5.

5.Collect alarm, log, and configuration information, and contact technical support personnel.

6.End

Copyright © Huawei Technologies Co., Ltd.