The IPv6 addresses in the IPv6 pool is exhausted.(IPv6PoolIndex=[IPv6PoolIndex],IPv6PoolName=[IPv6PoolName])
Addresses in the IPv6 address pool were exhausted and alarm was executed when an IPv6 address is not assigned.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Warning |
Mnemonic Code |
hwIPv6AddressExhaustAlarm |
Trap OID |
1.3.6.1.4.1.2011.6.8.2.2.0.20 |
MIB |
HUAWEI-IPPOOL-MIB |
Alarm ID |
0x0ae92013 |
Alarm Name |
hwIPv6AddressExhaustAlarm |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
BRASAM_1.3.6.1.4.1.2011.6.8.2.2.0.21 hwIPv6AddressExhaustAlarmResume |
Parameter | Description |
---|---|
IPv6PoolIndex |
index of address pool |
IPv6PoolName |
name of address pool |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.6.8.1.17.1.1 |
hwIPv6PoolIndex |
hwIPv6PoolIndex |
1.3.6.1.4.1.2011.6.8.1.17.1.2 |
hwIPv6PoolName |
hwIPv6PoolIndex |
1. Check the usage of the IPv6 address pool bound to the domain and check whether addresses are adequate for users who access the Internet through this domain.
2. Bind a new IPv6 address pool to the domain.
3. Check whether the alarm persists.
4. Collect alarm information, log information and configuration information, and then contact technical support personnel.
5. End.