BRASRUI_1.3.6.1.4.1.2011.5.25.361.2.7 hwBrasRuiTriggerErr

Trap Buffer Description

User services on the RUI backup device failed to be recovered for a long period of time.

User services on the RUI backup device failed to be recovered for a long period of time.

In VS mode, this trap is supported only by the admin VS.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwBrasRuiTriggerErr

Trap OID

1.3.6.1.4.1.2011.5.25.361.2.7

MIB

HUAWEI-BRAS-RUI-TRAP-MIB

Alarm ID

0x0dde2001

Alarm Name

hwBrasRuiTriggerErr

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Raise

Match trap

BRASRUI_1.3.6.1.4.1.2011.5.25.361.2.8 hwBrasRuiTriggerErrResume

Trap Buffer Parameters

None

VB Parameters

None

Impact on the System

Dual-device hot backup is affected.

Possible Causes

User services on the RUI backup device failed to be recovered for a long period of time.

Procedure

1.Check whether the board, subcard, or interface through which users go online is faulty.

  • If the board, subcard, or interface is faulty, go to step 2.
  • If the board, subcard, or interface is not faulty, go to step 3.

2.After the fault is rectified, wait for 90 minutes and check whether the alarm is cleared.

  • If the alarm is cleared, go to step 4.
  • If the alarm persists, go to step 3.

3.Collect alarm, log, and configuration information, and contact Huawei technical support personnel.

4.End.