Failed to apply for CAR resources for the EDSG.(Slot = [Slot])
The EDSG service failed to be activated because the board's CAR resources were insufficient.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Event |
Trap Severity |
Warning |
Mnemonic Code |
EDSGApplyCarResourceFailAlarm |
Trap OID |
1.3.6.1.4.1.2011.5.25.40.9.250.2.2 |
MIB |
HUAWEI-BRAS-VSM-MIB |
Alarm ID |
This is an event trap and does not involve alarm ID. |
Alarm Name |
This is an event trap and does not involve alarm name. |
Alarm Type |
This is an event trap and does not involve alarm type. |
Raise or Clear |
This is an event trap and does not involve alarm generation or clearance. |
Match trap |
- |
Parameter | Description |
---|---|
Slot |
Slot Num. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.40.9.250.1.2 |
hwVsmSlot |
- |
1. Add an interface board and check whether the trap is cleared.
2. Collect trap, log, and configuration information, and contact technical support personnel.
3. End.