The clock source is switched. (hwClockChassisId=[hwClockChassisId], hwClockPllId=[hwClockPllId], hwClockLastSourceName=[hwClockLastSourceName], hwClockCurSourceName=[hwClockCurSourceName], hwClockSrcSelChassisIndex=[hwClockSrcSelChassisIndex], hwClockSrcSelType=[hwClockSrcSelType], hwClockSrcSelMode=[hwClockSrcSelMode])
The clock source was switched.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Event |
Trap Severity |
Warning |
Mnemonic Code |
hwClockSourceSwitch |
Trap OID |
1.3.6.1.4.1.2011.5.25.186.1.8.1 |
MIB |
HUAWEI-CLOCK-MIB |
Alarm ID |
This is an event trap and does not involve alarm ID. |
Alarm Name |
This is an event trap and does not involve alarm name. |
Alarm Type |
This is an event trap and does not involve alarm type. |
Raise or Clear |
This is an event trap and does not involve alarm generation or clearance. |
Match trap |
- |
Parameter | Description |
---|---|
hwClockChassisId |
ID of the chassis where the clock source is located. The value is fixed to 1 for a single chassis. |
hwClockPllId |
ID of the clock source type. The options are as follows:
|
hwClockLastSourceName |
Name of the clock source before the switching. |
hwClockCurSourceName |
Name of the current clock source. |
hwClockSrcSelChassisIndex |
Index of the chassis where the clock source is located. In the case of a single chassis, the value is fixed to 1. |
hwClockSrcSelType |
Type of the clock source. The value can be:
|
hwClockSrcSelMode |
Clock source selection mode. The value can be:
|
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.186.1.7.4 |
hwClockChassisId |
- |
1.3.6.1.4.1.2011.5.25.186.1.7.6 |
hwClockPllId |
- |
1.3.6.1.4.1.2011.5.25.186.1.7.1 |
hwClockLastSourceName |
- |
1.3.6.1.4.1.2011.5.25.186.1.7.2 |
hwClockCurSourceName |
- |
1.3.6.1.4.1.2011.5.25.186.1.10.1.3 |
hwClockSrcSelMode |
hwClockSrcSelChassisIndex hwClockSrcSelType |
1. Run the display clock config command to check the running mode of the clock source.
2. Run the display clock config command to check the clock source selection mode.
3. Run the display clock source command to check whether the clock source status is normal.
4. Run the display clock source command to check whether the attributes of the clock source change.
5. Collect trap, log, and configuration information, and contact technical support.
6. End.