CLKM_1.3.6.1.4.1.2011.5.25.186.1.8.31 hwClockSourceSsmChange

Trap Buffer Description

The clock source SSM was changed. (hwClockChassisId=[hwClockChassisId], hwClockCurSourceName=[hwClockCurSourceName], hwClockOldSourceSsm=[hwClockOldSourceSsm], hwClockNewSourceSsm=[hwClockNewSourceSsm])

The SSM of the clock source changed.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwClockSourceSsmChange

Trap OID

1.3.6.1.4.1.2011.5.25.186.1.8.31

MIB

HUAWEI-CLOCK-MIB

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Name

This is an event trap and does not involve alarm name.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

-

Trap Buffer Parameters

Parameter Description

hwClockChassisId

Chassis ID. The value is fixed to 1 for a single chassis.

hwClockCurSourceName

Name of the current clock source.

hwClockOldSourceSsm

SSM before the change.

The options are as follows:

ssmUnk(0)

ssmPrc(2):

ssmSsua(4).

ssmSsub(8)

ssmSec(11)

ssmDnu(15).

ssmInvalid(255).

ssmPrtc(8194)

ssmEPrtc(8450)

ssmESec(8715).

ssmEPrc(8962).

hwClockNewSourceSsm

Current SSM.

The options are as follows:

ssmUnk(0)

ssmPrc(2):

ssmSsua(4).

ssmSsub(8)

ssmSec(11)

ssmDnu(15).

ssmInvalid(255).

ssmPrtc(8194)

ssmEPrtc(8450)

ssmESec(8715).

ssmEPrc(8962).

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.186.1.7.4

hwClockChassisId

-

1.3.6.1.4.1.2011.5.25.186.1.7.2

hwClockCurSourceName

-

1.3.6.1.4.1.2011.5.25.186.1.7.20

hwClockOldSourceSsm

-

1.3.6.1.4.1.2011.5.25.186.1.7.21

hwClockNewSourceSsm

-

Impact on the System

This log message is informational only, and services are not affected.

Possible Causes

Cause 1: The SSM received by the port changes.

Cause 2: The SSM configured on the interface changed.

Cause 3: The interface went Down, causing the SSM status to change.

Procedure

This log message is informational only, and no action is required.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >