DCNM_1.3.6.1.4.1.2011.5.25.300.1.3.1 hwIpRanDcnNeNumberOverLoad

Trap Buffer Description

DCN NE number overload start. (NeNumber=[NeNumber])

The number of NEs connected to the GNE exceeds the alarm threshold.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwIpRanDcnNeNumberOverLoad

Trap OID

1.3.6.1.4.1.2011.5.25.300.1.3.1

MIB

HUAWEI-IPRAN-DCN-MIB

Alarm ID

0x0001009b

Alarm Name

hwIpRanDcnNeNumberOverLoad

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DCNM_1.3.6.1.4.1.2011.5.25.300.1.3.2 hwIpRanDcnNeNumberOverLoadRecovery

Trap Buffer Parameters

Parameter Description

NeNumber

Indicates the NE quantity.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.300.1.2.1

hwIpRanDcnNeNumber

-

Impact on the System

This alarm has no adverse impacts on services.

Possible Causes

The DCN NE number exceeds the setting threshold

Procedure

1. Run the display dcn ne-info command to check whether the number of entries in the DCN core routing table has exceeded the upper limit.

2. Run the display this command in the DCN view to check the alarm threshold for the number of NEs connected to the GNE.

3. Collect alarm information and configuration information, and then contact technical support personnel. Replan the DCN subnets or change the alarm threshold for the number of NEs connected to the GNE.