DEVM_1.3.6.1.4.1.2011.5.25.129.2.1.5 hwEntityReset-66561

Trap Buffer Description

Physical entity reset. (EntityPhysicalIndex=[ULONG],BaseTrapSeverity=4, BaseTrapProbableCause=66561, BaseTrapEventType=5, EntPhysicalContainedIn=[ULONG], EntPhysicalName=[STRING], RelativeResource=[STRING], ReasonDescription=Because of heart beat loss,the entity of MPU <slotID> is resetting, not ready)

The physical entity reset because a part failed.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwEntityReset

Trap OID

1.3.6.1.4.1.2011.5.25.129.2.1.5

MIB

HUAWEI-BASE-TRAP-MIB

Alarm ID

0x08130094

Alarm Name

hwEntityReset

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.129.2.1.6 hwEntityResetDone-66561

Trap Buffer Parameters

Parameter Description

BaseTrapSeverity

Indicates the physical index.

BaseTrapProbableCause

Possible reason.

BaseTrapEventType

Indicates the possible cause of the trap.

EntityPhysicalIndex

Indicates the trap type.

EntPhysicalContainedIn

Indicates the parent index.

EntPhysicalName

Indicates the name of the entity such as a chassis.

RelativeResource

This object may contain a key word to indicate the relative resource of an entity.

ReasonDescription

To describe the reason of trap in DisplayString style.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.129.1.1

hwBaseTrapSeverity

-

1.3.6.1.4.1.2011.5.25.129.1.2

hwBaseTrapProbableCause

-

1.3.6.1.4.1.2011.5.25.129.1.3

hwBaseTrapEventType

-

1.3.6.1.2.1.47.1.1.1.1.4

entPhysicalContainedIn

entPhysicalIndex

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.129.1.4

hwBaseTrapRelativeResource

-

1.3.6.1.4.1.2011.5.25.129.1.5

hwBaseTrapReasonDescr

-

Impact on the System

1. If the slave MPU works normally after the automatic reset, no service will be affected.

2. If the slave MPU fails to be registered after the automatic reset, or the slave MPU is reset frequently, the reliability of the system may be affected. If the master/slave switchover occurs, all the services on the device will be interrupted. Take action immediately.

Possible Causes

Cause 1: A fault may occur on the ECM channel.

Cause 2: The CPU usage on the master MPU is too high.

Procedure

1. The slave MPU can restore automatically. Check whether the reset MPU works normally.

  • If so, go to Step 3.
  • If not, go to Step 2.

2. Replace an MPU. After the registration, check whether the trap is recovered.

  • If so, go to Step 4.
  • If not, go to Step 3.

3. Collect the trap information, log information, and configuration of the router, and contact technical support personnel.

4. End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.