Physical entity reset. (EntityPhysicalIndex=[ULONG],BaseTrapSeverity=4, BaseTrapProbableCause=66561, BaseTrapEventType=5, EntPhysicalContainedIn=[ULONG], EntPhysicalName=[STRING], RelativeResource=[STRING], ReasonDescription=Because of heart beat loss,the entity of MPU <slotID> is resetting, not ready)
The physical entity reset because a part failed.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwEntityReset |
Trap OID |
1.3.6.1.4.1.2011.5.25.129.2.1.5 |
MIB |
HUAWEI-BASE-TRAP-MIB |
Alarm ID |
0x08130094 |
Alarm Name |
hwEntityReset |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.129.2.1.6 hwEntityResetDone-66561 |
Parameter | Description |
---|---|
BaseTrapSeverity |
Indicates the physical index. |
BaseTrapProbableCause |
Possible reason. |
BaseTrapEventType |
Indicates the possible cause of the trap. |
EntityPhysicalIndex |
Indicates the trap type. |
EntPhysicalContainedIn |
Indicates the parent index. |
EntPhysicalName |
Indicates the name of the entity such as a chassis. |
RelativeResource |
This object may contain a key word to indicate the relative resource of an entity. |
ReasonDescription |
To describe the reason of trap in DisplayString style. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.129.1.1 |
hwBaseTrapSeverity |
- |
1.3.6.1.4.1.2011.5.25.129.1.2 |
hwBaseTrapProbableCause |
- |
1.3.6.1.4.1.2011.5.25.129.1.3 |
hwBaseTrapEventType |
- |
1.3.6.1.2.1.47.1.1.1.1.4 |
entPhysicalContainedIn |
entPhysicalIndex |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.129.1.4 |
hwBaseTrapRelativeResource |
- |
1.3.6.1.4.1.2011.5.25.129.1.5 |
hwBaseTrapReasonDescr |
- |
1. If the slave MPU works normally after the automatic reset, no service will be affected.
2. If the slave MPU fails to be registered after the automatic reset, or the slave MPU is reset frequently, the reliability of the system may be affected. If the master/slave switchover occurs, all the services on the device will be interrupted. Take action immediately.
1. The slave MPU can restore automatically. Check whether the reset MPU works normally.
2. Replace an MPU. After the registration, check whether the trap is recovered.
3. Collect the trap information, log information, and configuration of the router, and contact technical support personnel.
4. End.