DEVM_1.3.6.1.4.1.2011.5.25.129.2.1.9 hwEntityInvalid-67660

Trap Buffer Description

Physical entity failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[67660], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=Cause1:The second 48 V power supply failed: The second power module was not installed or The second power module failed. Cause2:One or both power supplies failed,No external power supply was available for one or both power modules. Cause3:The two PMU monitor buses failed.)

Physical entity failed.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwEntityInvalid

Trap OID

1.3.6.1.4.1.2011.5.25.129.2.1.9

MIB

HUAWEI-BASE-TRAP-MIB

Alarm ID

0x08130055

Alarm Name

hwEntityInvalid

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.129.2.1.10 hwEntityResume-67660

Trap Buffer Parameters

Parameter Description

BaseTrapSeverity

To describe the level of trap.

ProbableCause

To describe the probable cause of trap.

BaseTrapEventType

To describe the type of trap.

EntityPhysicalIndex

The index of the physical entity.

EntContainedIn

The value of entPhysicalIndex for the physical entity.

EntPhysicalName

The textual name of the physical entity.

RelativeResource

This object may contain a key word to indicate the relative resource of an entity.

ReasonDescription

To describe the reason of trap in DisplayString style.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.129.1.1

hwBaseTrapSeverity

-

1.3.6.1.4.1.2011.5.25.129.1.2

hwBaseTrapProbableCause

-

1.3.6.1.4.1.2011.5.25.129.1.3

hwBaseTrapEventType

-

1.3.6.1.2.1.47.1.1.1.1.4

entPhysicalContainedIn

entPhysicalIndex

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.129.1.4

hwBaseTrapRelativeResource

-

1.3.6.1.4.1.2011.5.25.129.1.5

hwBaseTrapReasonDescr

-

Impact on the System

When the second 48 V power supply failed:

Services will not be affected, but power supply reliability is low.

When one or both power supplies failed:

The power supply failure may lead to power supply insufficiency, which may cause board resetting due to loss of heartbeat packets. This indirectly affects services, and therefore this problem needs to be solved.

When both of the two PMUs are faulty:

Power module information cannot be monitored.

Possible Causes

Cause1:The second 48 V power supply failed:

The second power module was not installed or The second power module failed.

Cause2:One or both power supplies failed,No external power supply was available for one or both power modules.

Cause3:The two PMU monitor buses failed.

Procedure

The second 48 V power supply failed.

1. Run the display device command and check whether the second power supply is unavailable.

  • If so, go to Step 2.
  • If not, go to Step 3.

2. Install an additional power module and check whether the trap is cleared.

  • If so, go to Step 6.
  • If not, go to Step 3.

3. Run the display device command and check whether the power module works properly.

  • If so, go to Step 5.
  • If not, go to Step 4.

4. Replace the faulty power module and check whether the alarm is cleared.

  • If so, go to Step 6.
  • If not, go to Step 4.

5. Collect trap, log, and configuration information, and contact technical support.

6. End.